EXPLORE OUR HEALTH & WELLNESS BRANDS

ExactFit 3 Blood Pressure Monitor (BUA6150)

Question: How do I use my blood pressure monitor?

Answer:

Sit down, relax and stay as still as possible. Remove your watch and jewelry. Do not cross your legs and keep your feet flat on the ground.

1. Place the cuff on your left arm in direct contact with your skin. Cuff must be 0.8″-1.2″ (2-3 cm) above your elbow.
2. Make sure the tube is facing in the same direction as your hand and is running over the top of your arm.
3. Make sure the tube is not pinched. The cuff should feel tight but comfortable.
4. Turn the device on. Touch the [heart] icon to start.
5. Push button to take a reading.
6. The cuff will start to gently inflate. Keep still and do not speak while the reading is being taken.
7. After the air pressure has increased, the pulse is detected, the heart rate symbol will start flashing.
8. LCD Display will show the results and AHA indicator arrow after measurement. After using the device, turn it off by pressing the start button or automatically after 1 minute.

.

Question: How do I make sure I achieve an accurate reading?

Answer:

In order to get an accurate measurement, it is important to follow these rules:

– Always take readings at the same time of day, under the same conditions. Always measure on the same arm. The left arm is recommended.
– Do not take a measurement within 30 minutes of smoking, drinking coffee or tea or any form of exertion. These factors will influence the measurement.
– Ensure at least 5 minutes of quiet rest before measurements. If possible, it is recommended to rest 10 minutes before taking the measurement. Try to always use the same resting time before taking a measurement.
– If you want to take multiple measurements, wait approximately 3 minutes before repeating a measurement.

Question: How do I insert the batteries in my blood pressure monitor?

Answer: Remove the battery compartment cover at the bottom of the unit and insert 4 AA LR6 alkaline batteries with correct polarity (see symbol in the battery compartment). Note: ALWAYS reset date and time after replacing new batteries to make sure the measurement results are stored with correct date and time.

Question: How do I know which cuff size to use?

Answer:

For an accurate measurement, it is important to choose the correct size cuff which best fits your upper arm. Choose the cuff size according to your arm circumference and make sure the bottom of the cuff is 0.8″-1.2″ (2-3cm) above your elbow.

– Small/Medium Cuff = 8 3/4″ ~ 12 1/2″ (22~32cm) arm circumference
– Large/X-Large Cuff = 12 1/2″ ~16 1/2″ (32~42cm) arm circumference

Question: How do I select user A / user B?

Answer:

1. Make sure the Product is in power off mode.
2. Slide the user switch to user A or user B. The current user mode will flash on the LCD display.

Question: How do I set month, date and time?

Answer:

1. Switch off the device for the date/time setting.
2. Press the set button (4) to start the year setting, then the “year” will blink on display. Press (3) to adjust year by 1 step.
3. Press the set button (4) to start the month setting, then the “month” will blink on display, user can press adjust (3) to adjust month by 1 step.
4. Press set button (4) to start the day setting, then the “day” will blink on display, user can press adjust (3) to adjust day by 1 step.
5. Press set button (4) to start the hour setting, then the “hour” will blink on display, user can press adjust (3) to adjust hour by 1 step.
6. Press set button (4) to start the minute setting, then the “minute” will blink on display, user can press adjust (3) to adjust minute by 1 step.
7. Press set button (4) to end all the date/time setting, all blinking stops.

Note: Holding the adjust button will scroll the value.

Question: How do I access stored measurement data?

Answer:

Your blood pressure monitor can store the latest 40 readings for each user. After each blood pressure measurement, the systolic pressure, diastolic pressure, pulse rate and the time & date of specific day will be automatically stored. Memory #01 is always the most recent one. Once the memory is full, the oldest values will be overwritten.

1. Press memory button M(2) to review the stored data. The last memory data (sys/dia/pul) with measurement date/time, Irregular Heart Beat and AHA indicator will show on LCD.
2. Press memory button M(2) again to show the previous data. Ensure that the correct user; A or B, is selected before use.

Question: How do I clean my blood pressure monitor?

Answer:

To clean your blood pressure monitor, use a piece of cloth with water or mild cleansing agent to clean the case and then use a piece of dry cloth to wipe it dry. Use a piece of dry cloth to wipe the cuff when it is dirty.

NEVER use abrasive cleaning agents, thinners, or benzene for cleaning, and NEVER immerse the unit in water or other cleaning liquids.

Need further assistance?

Call Us

(800) 477 - 0457
Monday - Friday
9:00 am- 5:00 pm EST

Email Us

Email your questions to:
[email protected]

Braun Support Channel

Your questions answered for all Braun products

Question: What is my Braun Thermometer warranty?

Answer: This 3-year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty

Question: What should I do if my thermometer is displaying an Err message?

Answer: This will occur if the ambient temperature is not within the allowed operating range (50 – 104 °F or 10 – 40 °C.)  In order to resolve this, we would recommend you allow the thermometer to remain for 30 minutes in a room where the temperature is between 50 and 104 °F or 10 and 40 °C.

Question: What does a flashing display or no display mean when I turn on my thermometer?

Answer:

A flashing display indicates a system error. We suggest waiting 1 minute until the thermometer turns off by itself and then turns on again. If the problem persists, reset the thermometer by removing the batteries momentarily.

Question: What are the benefits to using a forehead thermometer? How do they work?

Answer: Similar to non-contact thermometers, a forehead thermometer is a quick and fuss-free way of measuring a child’s temperature that measures the infrared heat waves emitted thru the surface of the skin. The main difference is that you need to gently touch the center of the forehead to take a reading. It is a great choice for young squirmy children that are feeling under the weather.

Question: What are the benefits to using an ear thermometer?

Answer: The ear is a good site for temperature measurement because it reflects the core temperature of the body(1). Body temperature is regulated by the hypothalamus(2), which shares the same blood supply as the tympanic membrane(3). This means changes in core body temperature are usually detected sooner in the tympanic membrane than other areas. All Braun infrared ear thermometers feature ThermoScan® technology, which measure heat generated by the eardrum and surrounding tissue to give an accurate temperature on an easy to read digital display in seconds.

Citation:

[1] Guyton A C, Textbook of Medical Physiology, W.B. Saunders, Philadelphia, 2016, p 919.

[2] Guyton A C, Textbook of Medical Physiology, W.B. Saunders, Philadelphia, 2016, p 754-5.

[3] Netter H F, Atlas of Human Anatomy, Novartis Medical Education, East Hanover, NJ, 1997, pp 63, 95.

Question: Are Braun lens filters BPA free?

Answer: Yes, Braun disposable lens filters are BPA & latex free.

Question: How do I use Braun lens filters?

Answer: To avoid inaccurate measurements ALWAYS use this thermometer with a new, clean lens filter attached.

If the thermometer is accidentally used without a lens filter attached, clean the lens.

The lens filter indicator will blink to signal one is needed.

Attach a new lens filter by pushing the thermometer probe straight into the lens filter inside the box and then pulling out.

Note: The Braun ThermoScan® will not work unless a lens filter is attached.

For the next measurement, press Eject button to remove and discard used lens filter, and put on a new, clean lens filter. For models without and eject button (ThermoScan® 3 and 4), pull off lens filter and discard.

Question: How do I store my thermometer?

Answer: Store thermometer and lens filters in a dry location free from dust and contamination and away from direct sunlight. Always store the thermometer with the protective cap or with the cradle in place to prevent dirt and scratches from damaging the device.

Do not store this thermometer in temperature extremes below -13 °F or over 131 °F or in excessive humidity (above 95% relative humidity).

If thermometer is stored in a location that is cooler or warmer than where it will be used, allow it to acclimate to the room temperature for 10 minutes before taking the measurement.

Question: Does Braun offer a stick thermometer?

Answer: Braun does not offer a digital stick thermometer, but we recommend using the Vicks digital thermometers. They are clinically accurate, provide color-coded fever guidance and fast readings.

Question: Do Braun thermometers come with lens filters?

Answer: Yes. Lens filters are included with all our Ear thermometers. Please use a new lens filter after each use for an accurate reading.

Question: Do all Braun thermometers take the same size lens filter?

Answer: Yes. Our Braun lens filters are universal across all our Ear thermometers & Braun lens filters are the only brand to ensure an accurate reading when used with Braun thermometers.

Question: How do I store my thermometer & lens filters?

Answer: Store your thermometer and lens filters in a dry location free from dust and contamination and away from direct sunlight. Always store the thermometer with the protective cap or with the cradle in place to prevent dirt and scratches from damaging the device.
Do not store your thermometer in temperature extremes below -13 °F or over 131 °F or in excessive humidity (above 95% relative humidity). If the thermometer is stored in a location that is cooler or warmer than where it will be used, allow it to acclimate to the room temperature for 10 minutes before taking the measurement.

Question: What is Age Precision® Technology?

Answer: Clinical research shows the definition of fever changes as newborns grow into children & children grow into adults. The Age Precision feature takes the guesswork out of temperature taking, allowing you to select the appropriate age setting – 0-3 months, 3-36 months or 36+ months.

Question: What is Fever Guidance?

Answer: Temperature guidance helps you to better understand the meaning of your child's temperature with the color indicated on the display. The screen displays a green, yellow, or red backlight depending on the temperature reading.

It is important to note that a patient's temperature may be impacted by age, gender or medical condition, or by factors such as ambient temperature, time of day, medications taken or the temperature measurement site.

Question: What is ExacTemp®

Answer: ExacTemp® is a guidance system that confirms good position in the ear with a light and a beep to ensure accurate temperature measurement.